Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 278
Filtrar
2.
Artigo em Inglês | MEDLINE | ID: mdl-38609733

RESUMO

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society (HRS), the Asia Pacific HRS, and the Latin American HRS.

4.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38587017

RESUMO

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society, the Asia Pacific Heart Rhythm Society, and the Latin American Heart Rhythm Society .


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , América Latina , Resultado do Tratamento , Catéteres , Ásia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
5.
JTCVS Tech ; 23: 63-71, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38351990

RESUMO

Objective: The Impella 5.5 (Abiomed, Inc), a surgically implanted endovascular microaxial left ventricular assist device, is increasingly used worldwide and there have been more than 10,000 implants. The purpose of this study is to describe a large-volume, single-center experience with the use of the Impella 5.5. Methods: Data were obtained retrospectively from patients supported with the Impella 5.5 implanted at our institution from May 1, 2020, to December 31, 2022. Demographic, operative, and postoperative outcomes for each group are described. Results are reported in median (interquartile range) or n (%). The entire cohort was divided into 5 main groups based on the intention to treat at the time of the Impella 5.5 implantation: (1) patients who had a planned Impella 5.5 implanted at the time of high-risk cardiac surgery; (2) patients with cardiogenic shock; (3) patients bridged to a durable left ventricular assist device; (4) patients bridged to transplant; and (5) patients with postcardiotomy shock who received an unplanned Impella 5.5 implant. Results: A total of 126 patients were supported with the Impella 5.5. Overall survival to device explant was 76.2%, with 67.5% surviving to discharge. Midterm survival was assessed with a median follow-up time of 318 days and demonstrated an overall survival of 60.3% and a median of 650 days (549-752). Conclusions: Outcomes after using the Impella 5.5 are variable depending on the indication of use. Patient selection may be of utmost importance and requires further experience with this device to determine who will benefit from insertion.

7.
Innovations (Phila) ; 18(6): 565-573, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38013234

RESUMO

OBJECTIVE: A right minithoracotomy (RMT) is a minimally invasive surgical approach that has been increasingly performed for the concomitant Cox maze IV procedure (CMP) and mitral valve surgery (MVS). Little is known regarding whether long-term rhythm and survival outcomes are affected by the RMT as compared with the traditional median sternotomy (MS) approach. METHODS: Between April 2004 and April 2021, 377 patients underwent the concomitant CMP and MVS, of whom 38% had RMT. Propensity score matching yielded 116 pairs. Freedom from atrial tachyarrhythmias (ATA) was assessed with prolonged monitoring annually for 8 years. Survival, rhythm, and perioperative outcomes were compared. RESULTS: The unmatched RMT cohort had a greater freedom from ATA recurrence at 1 year (99% vs 90%, P = 0.001) and 3 years (94% vs 86%, P = 0.045). The matched RMT cohort had longer cardiopulmonary bypass (median: 215 [199 to 253] vs 170 [136 to 198] min, P < 0.001) and aortic cross-clamp (110 [98 to 124] vs 86 [71 to 102] min, P < 0.001) times but shorter intensive care time (48 [24 to 95] vs 71 [26 to 144] h, P = 0.001) and length of stay (8 [6 to 11] vs 10 [7 to 14] h, P < 0.001). More pacemakers (18% vs 4%, P < 0.001) and postoperative transfusions (57% vs 41%, P = 0.014) occurred in the MS cohort. The 30-day mortality (P = 0.651) and 8-year survival (P = 0.072) was not significantly different between the cohorts. CONCLUSIONS: Early 1-year and 3-year freedom from ATA recurrence was better in the RMT cohort compared with the MS cohort. Despite longer operative times, the RMT cohort had shorter lengths of stay, fewer postoperative transfusions, and fewer pacemakers placed.


Assuntos
Valva Mitral , Esternotomia , Humanos , Esternotomia/métodos , Valva Mitral/cirurgia , Procedimento do Labirinto , Resultado do Tratamento , Estudos Retrospectivos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos
8.
Eur J Cardiothorac Surg ; 64(4)2023 10 04.
Artigo em Inglês | MEDLINE | ID: mdl-37815836

RESUMO

OBJECTIVES: Malignancy is the leading cause of late mortality after orthotopic heart transplantation (OHT), and the burden of post-transplantation cancer is expected to rise in proportion to increased case volume following the 2018 heart allocation score change. In this report, we evaluated factors associated with de novo malignancy after OHT with a focus on skin and solid organ cancers. METHODS: Patients who underwent OHT at our institution between 1999 and 2018 were retrospectively reviewed (n = 488). Terminal outcomes of death and development of skin and/or solid organ malignancy were assessed as competing risks. Fine-Gray subdistribution hazards regression was used to evaluate the association between perioperative patient and donor characteristics and late-term malignancy outcomes. RESULTS: By 1, 5 and 10 years, an estimated 2%, 17% and 27% of patients developed skin malignancy, while 1%, 5% and 12% of patients developed solid organ malignancy. On multivariable Fine-Gray regression, age [1.05 (1.03-1.08); P < 0.001], government payer insurance [1.77 (1.20-2.59); P = 0.006], family history of malignancy [1.66 (1.15-2.38); P = 0.007] and metformin use [1.73 (1.15-2.59); P = 0.008] were associated with increased risk of melanoma and basal or squamous cell carcinoma. Age [1.08 (1.04-1.12); P < 0.001] and family history of malignancy [2.55 (1.43-4.56); P = 0.002] were associated with an increased risk of solid organ cancer, most commonly prostate and lung cancer. CONCLUSIONS: Vigilant cancer and immunosuppression surveillance is warranted in OHT recipients at late-term follow-up. The cumulative incidence of skin and solid organ malignancies increases temporally after transplantation, and key risk factors for the development of post-OHT malignancy warrant identification and routine monitoring.


Assuntos
Carcinoma de Células Escamosas , Transplante de Coração , Neoplasias , Neoplasias Cutâneas , Masculino , Humanos , Estudos Retrospectivos , Neoplasias/etiologia , Neoplasias/complicações , Transplante de Coração/efeitos adversos , Neoplasias Cutâneas/epidemiologia , Neoplasias Cutâneas/etiologia , Terapia de Imunossupressão/efeitos adversos , Carcinoma de Células Escamosas/etiologia , Fatores de Risco , Incidência
9.
JTCVS Tech ; 21: 106-108, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37854829

RESUMO

Objective: Even though severe tricuspid regurgitation is not uncommon after cardiac transplantation, primary severe tricuspid regurgitation is rare. We present such a case with additional complexities. Methods: The patient was 44-year-old man with a HeartWare durable left ventricular assist device (Heartware Inc) who received a temporary right ventricular assist device (RVAD) with a ProtekDuo cannula (LivaNova Inc USA) for refractory ventricular fibrillation and underwent a heart transplant as United Network for Organ Sharing Status 1, in the presence of partially compensated cardiogenic shock, renal failure. Given complex re-operative surgery in a volume-overloaded patient with unknown pulmonary vascular resistance, an RVAD cannula was preserved and re- inserted during cardiac transplant. Postoperatively he required hemodialysis, had severe primary tricuspid regurgitation discovered after RVAD removal and developed Enterobacter mediastinitis. He underwent complex tricuspid valve repair for flail tricuspid leaflet due to ruptured papillary muscle likely due to RVAD cannula injury, after multiple mediastinal washouts and was followed by delayed chest reconstruction. Results: The patient is doing well, 6 months after discharge to home, asymptomatic, without re-admissions, on renal recovery path, with no tricuspid regurgitation and good biventricular function. Conclusions: Replacing the tricuspid valve in presence of hemodialysis catheter, immunosuppression and mediastinitis could be high risk for endocarditis. Even though we have short-term follow-up, tricuspid valve repair can be an effective way of managing primary severe regurgitation especially when there is a desire or need to avoid valve replacement.

10.
Artigo em Inglês | MEDLINE | ID: mdl-37802331

RESUMO

BACKGROUND: The incidence of infective endocarditis (IE) is rapidly increasing. Contemporary outcomes following high-risk double valve surgery (DVS) for IE are not well described. METHODS: Between 2001 and 2021, 211 patients with IE underwent combined aortic and mitral valve surgery at a tertiary care referral center. Data from the Society of Thoracic Surgeons registry, including demographics, operative details, and outcomes, were collected. Risk factors for 30-day and 1-year-mortality were analyzed. Survival was analyzed using Kaplan-Meier and Cox proportional hazards modeling. RESULTS: The study cohort had a male preponderance (73%), with a median age of 56 years (interquartile range [IQR], 44 to 63 years). Forty-five patients (21%) had a history of intravenous (IV) drug abuse, 50 (24%) were on preoperative dialysis, and 50 (24%) had prosthetic valve endocarditis. Thirty-day and 1-year mortality were 14% (n = 30) and 30% (n = 61), respectively. On multivariable Cox regression adjusting for age, prosthetic valve endocarditis, postoperative intra-aortic balloon pump (IABP), history of dialysis (adjusted hazard ratio [aHR], 1.9; 95% confidence interval [CI], 1.3 to 2.9; P = .002) and IV drug abuse (aHR, 2.0; 95% CI, 1.1-3.5; P = .02) were predictive of decreased survival. Undergoing surgery after 2010 was predictive of improved survival (aHR, 0.5; 95% CI, 0.3 to 0.8; P = .006). These patients were more likely to undergo urgent/emergent surgery (83% vs 29%; P < .001) and less likely to have an aortic root abscess (40% vs 58%; P = .03) or to require the commando procedure (13% vs 33%; P = .002). CONCLUSIONS: In this large series evaluating outcomes of DVS for IE in the modern era, although the mortality risk remained elevated, improving outcomes may be associated with earlier surgical intervention before significant disease progression. Multidisciplinary evaluation for complex IE may be considered to better understand the optimal timing and repair strategy.

11.
JTCVS Tech ; 20: 58-70, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37555041

RESUMO

Objective: To develop a minimally invasive, reproducible model of chronic severe mitral regurgitation (MR) that replicates the clinical phenotype of left atrial (LA) and left ventricular dilation and susceptibility to atrial fibrillation. Methods: Under transesophageal echocardiographic guidance, chordae tendinae were avulsed using endovascular forceps until the ratio of regurgitant jet area to LA area was ≥70%. Animals survived for an average of 8.6 ± 1.6 months (standard deviation) and imaged with monthly transthoracic echocardiography (TTE). Animals underwent baseline and preterminal magnetic resonance imaging. Terminal studies included TTE, transesophageal echocardiography, and rapid atrial pacing to test inducibility of atrial tachyarrhythmias. Results: Eight dogs underwent creation of severe MR and interval monitoring. Two were excluded-one died from acute heart failure, and the other had resolution of MR. Six dogs underwent the full experimental protocol; only one required medical management of clinical heart failure. MR remained severe over time, with a mean terminal regurgitant jet area to LA area of 71 ± 14% (standard deviation) and regurgitant fraction of 52 ± 11%. Mean LA volume increased over 130% (TTE: 163 ± 147%, P = .039; magnetic resonance imaging: 132 ± 54%, P = .011). Mean left ventricular end-diastolic volume increased by 38 ± 21% (P = .008). Inducible atrial tachyarrhythmias were seen in 4 of 6 animals at terminal surgery, and none at baseline. Conclusions: Within the 6 dogs that successfully completed the full experimental protocol, this model replicated the clinical phenotype of severe MR, which led to marked structural and electrophysiologic cardiac remodeling. This model allowed for precise measurements at repeated time points and will facilitate future studies to elucidate the mechanisms of atrial and ventricular remodeling secondary to MR and the pathophysiology of valvular atrial fibrillation.

12.
Ann Thorac Surg ; 116(2): 307-313, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36935027

RESUMO

BACKGROUND: Bipolar radiofrequency (RF) clamps are commonly used during surgical ablation for atrial fibrillation (AF). This study examined the efficacy of an irrigated bipolar RF clamp to create transmural lesions in an ex vivo human heart model. METHODS: Ten donor hearts, turned down for transplantation, were explanted and arrested with cold cardioplegia. The ablations of the Cox Maze IV procedure were performed using the Cardioblate LP (Medtronic, Inc) irrigated bipolar RF clamp. In the first 5 hearts, each lesion was created with a single application of RF, whereas in the remaining 5 hearts, each lesion was created with a double application of RF without unclamping. Each lesion was cross-sectioned and stained with 2,3,5-triphenyl-tetrazolium chloride to assess ablation depth and transmurality. RESULTS: A total of 100 lesions were analyzed. In the single-ablation group, 222 of 260 sections (85%) and 37 of 50 lesions (74%) were transmural. The efficacy improved significantly in the double-ablation group, in which 348 of 359 sections (97%, P < .001) and 46 of 50 lesions (92%, P = .017) were transmural. Overall, in nontransmural lesions, the epicardial fat thickness was significantly greater (1.69 ± 0.70 mm vs 0.45 ±0.10 mm, P < .001) than the transmural lesions. CONCLUSIONS: A single ablation on human atrial tissue with an irrigated bipolar RF clamp was insufficient to reliably create transmural lesions, but a double ablation significantly increased the lesion and section transmurality. Nontransmural lesions were associated with significantly thicker layers of epicardial fat, which likely decreased tissue energy delivery due to the higher resistance of fat to current flow.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Transplante de Coração , Ablação por Radiofrequência , Humanos , Ablação por Cateter/métodos , Doadores de Tecidos , Átrios do Coração/cirurgia , Fibrilação Atrial/cirurgia
14.
Ann Thorac Surg ; 115(4): 929-938, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36610532

RESUMO

BACKGROUND: Current guidelines recommend a target international normalized ratio (INR) range of 2.5 to 3.5 in patients with a mechanical mitral prosthesis. The Prospective Randomized On-X Anticoagulation Clinical Trial (PROACT) Mitral randomized controlled noninferiority trial assessed safety and efficacy of warfarin at doses lower than currently recommended in patients with an On-X (Artivion, Inc) mechanical mitral valve. METHODS: After On-X mechanical mitral valve replacement, followed by at least 3 months of standard anticoagulation, 401 patients at 44 North American centers were randomized to low-dose warfarin (target INR, 2.0-2.5) or standard-dose warfarin (target INR, 2.5-3.5). All patients were prescribed aspirin, 81 mg daily, and encouraged to use home INR testing. The primary end point was the sum of the linearized rates of thromboembolism, valve thrombosis, and bleeding events. The design was based on an expected 7.3% event rate and 1.5% noninferiority margin. RESULTS: Mean patient follow-up was 4.1 years. Mean INR was 2.47 and 2.92 (P <.001) in the low-dose and standard-dose warfarin groups, respectively. Primary end point rates were 11.9% per patient-year in the low-dose group and 12.0% per patient-year in the standard-dose group (difference, -0.07%; 95% CI, -3.40% to 3.26%). The CI >1.5%, thus noninferiority was not achieved. Rates (percentage per patient-year) of the individual components of the primary end point were 2.3% vs 2.5% for thromboembolism, 0.5% vs 0.5% for valve thrombosis, and 9.13% vs 9.04% for bleeding. CONCLUSIONS: Compared with standard-dose warfarin, low-dose warfarin did not achieve noninferiority for the composite primary end point. (PROACT Clinicaltrials.gov number, NCT00291525).


Assuntos
Implante de Prótese de Valva Cardíaca , Tromboembolia , Trombose , Humanos , Varfarina/efeitos adversos , Anticoagulantes/efeitos adversos , Estudos Prospectivos , Valva Mitral/cirurgia , Tromboembolia/etiologia , Tromboembolia/prevenção & controle , Hemorragia/etiologia , Trombose/etiologia , Implante de Prótese de Valva Cardíaca/efeitos adversos
16.
JTCVS Open ; 16: 292-302, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38204711

RESUMO

Objectives: The mechanism by which mitral valve (MV) disease leads to atrial fibrillation (AF) remains poorly understood. Delayed-enhancement cardiac magnetic resonance imaging (DE-MRI) has been used to assess left atrial (LA) fibrosis in patients with lone AF before catheter ablation; however, few studies have used DE-MRI to assess MV-induced LA fibrosis in patients with or without AF undergoing MV surgery. Methods: Between March 2018 and September 2022, 38 subjects were enrolled; 15 age-matched controls, 14 patients with lone mitral regurgitation (MR), and 9 patients with MR and AF (MR + AF). Indexed LA volume, total LA wall, and regional LA posterior wall (LAPW) enhancement were defined by the DE-MRI. One-way analysis of variance was performed. Results: LA volume and LA enhancement were associated (r = 0.451, P = .004). LA volume differed significantly between controls (37.1 ± 10.6 mL) and patients with lone MR (71.0 ± 35.9, P = .020 and controls and patients with MR + AF (99.3 ± 47.4, P < .001). The difference in LA enhancement was significant between MR + AF (16.7 ± 9.6%) versus controls (8.3 ± 3.9%, P = .006) and MR + AF versus lone MR (8.0 ± 4.8%, P = .004). Similarly, the was significantly more LAPW enhancement in the MR + AF (17.5 ± 8.7%) versus control (9.2 ± 5.1%, P = .011) and MR + AF versus lone MR (9.8 ± 6.0%, P = .020). Conclusions: Patients with MR + AF had significantly more total and LAPW fibrosis compared with both controls and lone MR. Volume and delayed enhancement were associated, but there was no difference between MR and MR + AF.

17.
Innovations (Phila) ; 17(5): 409-415, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36217760

RESUMO

OBJECTIVE: Expert consensus guidelines recommend surgical ablation (SA) for patients with symptomatic atrial fibrillation (AF), but less than half of patients with AF undergoing cardiac procedures receive concomitant SA. Complete isolation of the left atrial posterior wall (LAPW) has been shown to be the most critical part of the Cox maze procedure. The purpose of this study was to investigate the performance of a novel radiofrequency (RF) bipolar device, EnCompass™ (AtriCure, Inc., Mason, OH, USA), designed to isolate the LAPW in a single application. METHODS: Five adult pigs underwent SA in a beating heart model. After a single ablation, the heart was arrested, explanted, and stained with triphenyl-tetrazolium-chloride for histological assessment. Each lesion was sectioned, and the ablation depth, muscle, and fat thickness were determined. The lesion width, energy delivery, and ablation times were compared with those from a reference RF clamp (Synergy™, AtriCure). RESULTS: Transmurality was documented in 100% of lesions (5 of 5) and cross sections (160 of 160). Electrical isolation was documented in every instance. There was no evidence of clot, charring, or pulmonary vein stenosis. Compared with the reference clamp, the lesions created by the EnCompass™ clamp were 1.5 times wider on average. The average energy delivered was 5 times higher over a duration that was 4.5 times longer due to the increased volume of tissue ablated. CONCLUSIONS: The EnCompass™ clamp reproducibly created transmural isolation of the LAPW with a single application. This may allow for simplification of the SA strategy and increased adoption of AF treatment during concomitant surgery.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Suínos , Animais , Fibrilação Atrial/cirurgia , Átrios do Coração/cirurgia , Resultado do Tratamento
18.
Ann Thorac Surg ; 2022 01 28.
Artigo em Inglês | MEDLINE | ID: mdl-35101419

RESUMO

This article has been withdrawn at the request of the author(s) and/or editor. The Publisher apologizes for any inconvenience this may cause. The full Elsevier Policy on Article Withdrawal can be found at https://www.elsevier.com/about/our-business/policies/article-withdrawal.

19.
J Thorac Cardiovasc Surg ; 163(1): 124-134.e8, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-33012541

RESUMO

OBJECTIVE: Left ventricular assist device (LVAD) implantation has been shown to increase allosensitization before orthotopic heart transplantation, but the influence of LVAD support on posttransplant rejection is controversial. This study examines the postoperative incidence of acute cellular rejection (ACR) in patients bridged with continuous flow LVAD (CF-LVAD) relative to primary transplant (Primary Tx). METHODS: All patients who underwent orthotopic heart transplantation at our institution between July 2006 and March 2019 were retrospectively reviewed (n = 395). Patients were classified into Primary Tx (n = 145) and CF-LVAD (n = 207) groups. Propensity score matching on 13 covariates implemented a 0.1 caliper logistic model with nearest neighbor 1:1 matching. Development of moderate to severe (ie, 2R/3R) rejection was evaluated using a competing risks model. Potential predictors of 2R/3R ACR were evaluated using Fine-Gray regression on the marginal subdistribution hazard. RESULTS: Propensity score matching yielded 122 patients in each group (n = 244). At 12 and 24 months, the cumulative incidence of 2R/3R ACR was 17% and 23% for the CF-LVAD group and 26% and 31%, respectively, for the Primary Tx group (P = .170). CF-LVAD was not predictive of 2R/3R rejection on multivariable Fine-Gray regression (subdistribution hazard ratio, 0.73; 95% confidence interval, 0.40-1.33; P = .301). There was no difference in the 5-year incidence of antibody mediated rejection (10% [n = 12] vs 9% [n = 11]; P = .827). CONCLUSIONS: After adjusting for covariates, CF-LVAD was not associated with an increased risk of moderate to severe ACR during the 24 months after cardiac transplantation. Further investigation is warranted with larger cohorts, but CF-LVAD may have minimal influence on posttransplant ACR.


Assuntos
Rejeição de Enxerto , Insuficiência Cardíaca/cirurgia , Coração Auxiliar/estatística & dados numéricos , Efeitos Adversos de Longa Duração , Cuidados Pré-Operatórios , Medição de Risco , Anticorpos/sangue , Feminino , Rejeição de Enxerto/diagnóstico , Rejeição de Enxerto/epidemiologia , Rejeição de Enxerto/imunologia , Transplante de Coração/efeitos adversos , Transplante de Coração/métodos , Humanos , Incidência , Efeitos Adversos de Longa Duração/diagnóstico , Efeitos Adversos de Longa Duração/epidemiologia , Efeitos Adversos de Longa Duração/imunologia , Masculino , Pessoa de Meia-Idade , Cuidados Pré-Operatórios/instrumentação , Cuidados Pré-Operatórios/métodos , Pontuação de Propensão , Modelos de Riscos Proporcionais , Medição de Risco/métodos , Medição de Risco/estatística & dados numéricos , Estados Unidos
20.
J Thorac Cardiovasc Surg ; 163(2): 629-641.e7, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-32563577

RESUMO

OBJECTIVE: Surgical ablation of atrial fibrillation (AF) is indicated both in patients with AF undergoing concomitant cardiac surgery and in those who have not responded to medical and/or catheter-based ablation therapy. This study examined our long-term outcomes following the Cox-Maze IV procedure (CMP-IV). METHODS: Between May 2003 and March 2018, 853 patients underwent either biatrial CMP-IV (n = 765) or a left-sided CMP-IV (n = 88) lesion set with complete isolation of the posterior left atrium. Freedom from atrial tachyarrhythmia (ATA) was assessed for up to 10 years. Rhythm outcomes were compared in multiple subgroups. Predictors of recurrence were determined using Fine-Gray regression, allowing for death as the competing risk. RESULTS: The majority of patients (513/853, 60%) had nonparoxysmal AF. Twenty-four percent of patients (201/853) had not responded to at least 1 catheter-based ablation. Prolonged monitoring was used in 76% (647/853) of patients during their follow-up. Freedom from ATA was 92% (552/598), 84% (213/253), and 77% (67/87) at 1, 5, and 10 years, respectively. By competing risk analysis, incidence of first ATA recurrence was 11%, 23%, and 35% at 1, 5, and 10 years, respectively. On Fine-Gray regression, age, peripheral vascular disease, nonparoxysmal AF, left atrial size, early postoperative ATAs, and absence of sinus rhythm at discharge were the predictors of first ATA recurrence over 10 years of follow-up. CONCLUSIONS: The CMP-IV had an excellent long-term efficacy at maintaining sinus rhythm. At late follow-up, the results of the CMP-IV remained superior to those reported for catheter ablation and other forms of surgical ablation for AF. Age, left atrial size, and nonparoxysmal AF were the most relevant predictors of late recurrence.


Assuntos
Fibrilação Atrial/cirurgia , Átrios do Coração/cirurgia , Procedimento do Labirinto , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Função do Átrio Esquerdo , Bases de Dados Factuais , Feminino , Átrios do Coração/fisiopatologia , Frequência Cardíaca , Humanos , Masculino , Procedimento do Labirinto/efeitos adversos , Pessoa de Meia-Idade , Recidiva , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA